Ammeter burden

Lab · 10 min

A 1.5 V cell drives a 10 Ω resistor, with the multimeter in series, on amps, to measure the current.

What current should flow?

Answer in mA.

The meter is on its mA range. Press Run and open the multimeter. What does it read?

Answer in mA.

Current has to flow through an ammeter, and inside it is a small resistor, the shunt, whose voltage it measures. That resistance, the meter's burden, is in series with your circuit.

On the mA range the shunt is 1.8 Ω. Next to a 10 Ω resistor, that's not small. The cell now drives 11.8 Ω:

I=1.5 V10+1.8 Ω=127 mA

The 10 A range uses a far smaller shunt, 0.01 Ω, for big currents. Switch the meter to the 10 A range and read it again.

If you know the rest of the loop's resistance, you can correct a burdened reading. The meter's current flowed through R+Rburden; without the meter it flows through R alone, from the same voltage:

Itrue=Iread×R+RburdenR

A meter on its µA range (100 Ω burden) reads 0.909 mA in a loop whose resistance is 1 kΩ. What is the true current?

Answer in mA.

You're measuring about 5 mA through a 220 Ω resistor and an LED. Which range should you use?

  • The mA range: its 1.8 Ω is under 1% of 220 Ω, and it shows tenths of a milliamp
  • The µA range: it's the most sensitive
  • The 10 A range: it has the smallest burden

Ammeter burden:

  • an ammeter is in series, so its own resistance, the burden, adds to the circuit's;
  • more sensitive ranges have bigger burdens: 0.01 Ω on 10 A, 1.8 Ω on mA, 100 Ω on µA;
  • in a low-resistance circuit the burden lowers the current you're measuring;
  • correct a reading with Itrue=Iread(R+Rburden)/R.