Bridge with a sensor
A bridge is the classic way to read a sensor. One arm is a reference: two equal resistors, holding their midpoint at exactly half the supply. The other arm is the sensor arm: a fixed resistor and the sensor. The meter between the midpoints reads zero at one chosen temperature, and swings one way or the other as it gets warmer or colder.
The sensor is the 10 kΩ NTC thermistor from the dividers module: 10 kΩ at 25 °C, less when warmer, more when colder. The reference arm is built: two 22 kΩ resistors.
You want the bridge to read zero at 25 °C. What fixed resistor should go with the thermistor?
Answer in Ω.
Now build the sensor arm: the thermistor and a 10 kΩ resistor in series from the + rail to the − rail, with wires. Then put the meter across the bridge.
One more requirement: the reading must be positive when it's warmer than 25 °C and negative when it's colder. Which part goes on top, and which probe goes where, decides the sign.
Press Run, then click the thermistor and try its temperature either side of 25 °C.
At 50 °C the thermistor is about 3.59 kΩ. With the thermistor on top of the 10 kΩ, what does the bridge read?
Answer in V.
Why read the thermistor with a bridge, rather than a single divider and a voltmeter to the − rail?
- The bridge reads zero at the set point, so small changes show up clearly and don't depend on the battery's exact voltage
- The bridge makes the thermistor more sensitive
- A divider can't be used with a thermistor
A sensor bridge:
- a reference arm of equal resistors holds half the supply;
- the sensor arm's fixed resistor equals the sensor at the set point, so the bridge reads zero there;
- which part is on top, and which way round the meter is, sets the sign of the reading either side;
- the reading isn't linear in temperature, because the thermistor isn't.