Finding faults with a meter

Debug · 12 min

This LED circuit looks right, but the LED stays dark. Something on the board is faulty, and it doesn't show.

Trace it with the meter on volts: black on the − rail and left there, and red moved from point to point, starting at the battery's + side. Where current flows, the voltage falls a bit at each part. Where it doesn't flow, nothing falls, until the break.

Press Run. Measure the + rail, the resistor's far end (column 6), and the LED's − leg (column 7). Where does the 9 V disappear?

  • Between the LED's − leg and the − rail: the black wire
  • Across the resistor
  • Across the LED

Replace the black wire: click it and delete it, then add a new wire from column 7 to the − rail.

Three LEDs, each with its own resistor, in parallel. The middle one is dark.

Trace it with the meter on volts: black on the − rail and left there, and red moved from point to point, starting at the battery's + side. Measure across each LED: red on its + leg, black on its − leg. What's wrong with the middle one?

  • It's shorted: 0 V across it, though its resistor carries current
  • It's open: no current flows in its branch
  • Its resistor is missing

Replace the middle LED with a new one from the drawer, its + leg (the longer one) towards the resistor.

A part has the full supply voltage across it, but no current flows in its branch. What's the most likely fault?

  • That part is open
  • That part is shorted
  • The battery is flat

Finding faults with a meter:

  • black on the − rail; walk red along the circuit from the supply;
  • the voltage should fall only across parts that carry current;
  • the full voltage across one part means it's open; 0 V across a part with current through it means it's shorted;
  • find it first, then replace it.