Measuring current
You've measured voltage by touching the probes across two points. Current is different: it is charge flowing through the circuit, so to measure it the meter has to be in the path, with all the current going through the meter itself.
That means opening the loop and closing it again with the meter.
Here's an LED circuit. Press Run to light it.
First open the loop. Click the black wire to select it and delete it (the Delete key, or the bin button).
Now close the gap with the meter. Open the multimeter, switch it to Amps, and put the red probe in the LED's short-leg column and the black probe on the black − rail.
The LED lights again, with its current going through the meter. What does the meter read?
Answer in mA.
Here's the same loop with three meters in it: one before the resistor, one between the resistor and the LED, and one after the LED.
Before you run it: how will the three readings compare?
- Biggest before the resistor, then smaller after each part
- Smallest before the resistor, then bigger after each part
- All three the same
Press Run and open the multimeter to see all three.
A very common slip: someone forgets the meter is set to amps and touches its probes across the LED, the way you would to measure a voltage.
That's what this circuit has. What will happen to the LED when it runs?
- It lights as usual
- It goes dark
- It gets brighter
Press Run and see.
That time the resistor still limited the current, so no harm was done. Which of these placements, with the meter on amps, would be the dangerous one?
- In a gap between the resistor and the LED
- In place of the wire from the + rail to the resistor
- Red probe on the + rail, black probe on the − rail
What you've found:
- To measure current, break the loop and put the meter in series, in the gap.
- Current is the same everywhere in a single loop.
- An ammeter is nearly a wire. Across a part it shorts it; across the battery it shorts everything.
On a real bench a multimeter has a separate socket for the red lead when measuring current, usually marked mA or A. Leaving the lead in that socket and then trying to measure a voltage is the most common way to blow a meter's fuse.